{"product_id":"24-port-gigabit-smart-poe-switch-ds-3e1526p-si","title":"DS-3E1526P-SI Commutateur POE intelligent Gigabit 24 ports","description":"\u003cdiv data-product-description-path=\"\/content\/manufacturer\/en\/products\/transmission\/Network-Switches\/smart-managed-series\/ds-3e1526p-si\/jcr:content\/root\/responsivegrid\/product-description\" class=\"product-description-container\"\u003e\n\u003cdiv data-product-page=\"\/content\/manufacturer\/en\/products\/transmission\/Network-Switches\/smart-managed-series\/ds-3e1526p-si\" data-product-number=\"M000043339\" data-product-name=\"DS-3E1526P-SI\" class=\"product_description-wrapper eols-wrapper\"\u003e\n\u003ch2 class=\"prod_name\"\u003e\u003cspan class=\"prod_name-content\"\u003eCommutateur POE intelligent Gigabit 24 ports\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul class=\"product_description_item-list\"\u003e\n\u003cli class=\"product_description_item\"\u003e24 ports PoE Gigabit et 2 ports fibre optique Gigabit.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003eNorme IEEE 802.3at\/af pour les ports PoE.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003eGestion de la topologie du réseau, poussée d'alarme, surveillance de l'état du réseau.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003eProtection contre les surtensions 6 KV pour les ports PoE.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003eLa caméra AF\/AT peut atteindre jusqu'à 300 m en mode étendu.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003eChien de garde PoE pour détecter et redémarrer automatiquement les caméras qui ne répondent pas.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003eDivers protocoles de gestion de couche 2 tels que STP\/RSTP, VLAN, agrégation de liens, SNMP, QoS, etc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"product_more_out\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c!--Parameter--\u003e\n\u003cdiv class=\"firmware-container\"\u003e\n\u003cp\u003eModèles disponibles :\u003c\/p\u003e\n\u003cdiv class=\"ordermodel-list\"\u003e\n\u003cdiv class=\"ordermodel-item\"\u003eDS-3E1526P-SI\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eDonnées produit\u003c\/h2\u003e\n\u003cdiv class=\"tech-specs-items-description-wrap\"\u003e\n\u003cul data-target=\"Network Parameters\" class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\u003cspan class=\"tech-specs-items-description__title--heading\"\u003eParamètres réseau\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003ePorts\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePort PoE 24 × 1 Gbit\/s, port fibre optique 2 × 1 Gbit\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eType de port\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePort RJ45, full duplex, adaptatif MDIMDI-X\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eNorme\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eIEEE 802.3,IEEE 802.3u,IEEE 802.3x,IEEE 802.3ab,IEEE 802.3z\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eMode de transfert\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eCommutation Store-and-Forward\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eMode de fonctionnement\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eMode standard (par défaut), mode étendu\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eTableau des adresses MAC\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e8K\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eCapacité de commutation\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e52 Gbit\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eTaux de transfert de paquets\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e36,688 Mpp\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eCache interne\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e4,1 Mbits\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-target=\"PoE Power Supply\" class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\u003cspan class=\"tech-specs-items-description__title--heading\"\u003eAlimentation PoE\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eNorme PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eIEEE 802.3af, IEEE 802.3at\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eBroche d'alimentation PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePortée finale : 1\/2(-), 3\/6(+)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003ePort PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePoE : ports 1 à 24\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eMax. Alimentation portuaire\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e30 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eBudget de puissance PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e370 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-target=\"Software Function\" class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\u003cspan class=\"tech-specs-items-description__title--heading\"\u003eFonction logicielle\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eEntretien de l'appareil\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePrend en charge la mise à niveau à distance, la restauration des paramètres par défaut, l'affichage des journaux, la configuration des paramètres réseau de base, la configuration de l'importation et de l'exportation et la synchronisation de l'heure.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eConfiguration des ports\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePrise en charge de la configuration du débit de port, du contrôle de flux et de l'activation des ports.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eLongue portée\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eTransmission jusqu'à 300 m\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eConfiguration PoE\u003c\/span\u003e\n\u003cp class=\"mb-p\"\u003eChien de garde PoE : les ports 1 à 24 détectent et redémarrent automatiquement les caméras qui ne répondent pas.\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003eActivation PoE : pris en charge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eLimitation du débit du port\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eLimitation de débit pour les ports d'entrée et de sortie\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eContrôle des tempêtes \u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eContrôle des tempêtes de monodiffusion, multidiffusion et diffusion inconnues\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eMise en miroir des ports\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePris en charge\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eAgrégation de liens\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePrise en charge de l'agrégation de liens statiques.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eIsolation des ports\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eLes ports d'un groupe d'isolation ne peuvent pas communiquer entre eux.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eQoS\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePlanification WRR et SP et priorité des ports\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eVLAN\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e4094 VLAN\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eSTP\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eSTP et RSTP\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eSNMP\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eSNMPv1 et SNMPv2c pris en charge pour obtenir des informations sur les nœuds du système et des interfaces\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eLLDP\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eLLDP pris en charge pour la configuration des ports, la configuration globale et la découverte des voisins\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eDHCP\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePris en charge\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-target=\"General\" class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\u003cspan class=\"tech-specs-items-description__title--heading\"\u003eGénéral\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eCoquille\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eMatériau métallique\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003ePoids net\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e2,975 kg (6,56 livres)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003ePoids brut\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e3,535 kg (7,79 livres)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eDimensions (L × H × P)\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e440,00 mm × 44,00 mm × 221,00 mm (17,32'' × 1,73'' × 8,70'')\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eTempérature de fonctionnement\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e-10 °C à 55 °C (14 °F à 131 °F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eTempérature de stockage\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e-40 °C à 85 °C (-40 °F à 185 °F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eHumidité de fonctionnement\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e5% à 95% (sans condensation)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eHumidité relative\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e5% à 95% (sans condensation)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eAlimentation\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e100 à 240 VCA, 50\/60 Hz, max. 6,3 A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eMax. Consommation d'énergie\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e400 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eConsommation d'énergie au repos\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e30 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-target=\"Approval\" class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\u003cspan class=\"tech-specs-items-description__title--heading\"\u003eApprobation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eCEM\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eFCC (47 CFR Partie 15, Sous-partie B) ; CE-EMC (EN 55032 : 2015, EN IEC 61000-3-2 : 2019, EN 61000-3-3 : 2013+A1 : 2019, EN 50130-4 : 2011 +A1 : 2014, EN 55035 : 2017) ; IC (ICES-003 : numéro 6) ; MRC (AS\/NZS CISPR 32 : 2015)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eSécurité\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eUL (UL 60950-1) ; CB (IEC 60950-1:2005, AMD1:2009, AMD2:2013, IEC 62368-1 : 2014 (deuxième édition); CE-LVD (EN 60950-1 : 2006 + A11 : 2009 +A1 : 2010+A12 : 2011+A2 : 2013, EN 62368-1 : 2014+A11 : 2017)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eChimie\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eCE-RoHS (2011\/65\/UE) ; DEEE (2012\/19\/UE) ; Reach (Règlement (CE) n°1907\/2006)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tech-specs-items-description-wrap\"\u003e\n\u003cul class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003ePorts\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePort PoE 24 × 1 Gbit\/s, port fibre optique 2 × 1 Gbit\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eType de port\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePort RJ45, full duplex, adaptatif MDIMDI-X\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eNorme\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eIEEE 802.3,IEEE 802.3u,IEEE 802.3x,IEEE 802.3ab,IEEE 802.3z\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eMode de transfert\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eCommutation Store-and-Forward\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eMode de fonctionnement\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eMode standard (par défaut), mode étendu\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eTableau des adresses MAC\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e8K\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eCapacité de commutation\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e52 Gbit\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eTaux de transfert de paquets\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e36,688 Mpp\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eCache interne\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e4,1 Mbits\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tech-specs-items-description-wrap\"\u003e\n\u003cul class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eNorme PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eIEEE 802.3af, IEEE 802.3at\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eBroche d'alimentation PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePortée finale : 1\/2(-), 3\/6(+)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003ePort PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePoE : ports 1 à 24\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eMax. Alimentation portuaire\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e30 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eBudget de puissance PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e370 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tech-specs-items-description-wrap\"\u003e\n\u003cul class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eEntretien de l'appareil\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePrend en charge la mise à niveau à distance, la restauration des paramètres par défaut, l'affichage des journaux, la configuration des paramètres réseau de base, la configuration de l'importation et de l'exportation et la synchronisation de l'heure.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eConfiguration des ports\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePrise en charge de la configuration du débit de port, du contrôle de flux et de l'activation des ports.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eLongue portée\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eTransmission jusqu'à 300 m\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eConfiguration PoE\u003c\/span\u003e\n\u003cp class=\"mb-p\"\u003eChien de garde PoE : les ports 1 à 24 détectent et redémarrent automatiquement les caméras qui ne répondent pas.\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003eActivation PoE : pris en charge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eLimitation du débit du port\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eLimitation de débit pour les ports d'entrée et de sortie\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eContrôle des tempêtes \u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eContrôle des tempêtes de monodiffusion, multidiffusion et diffusion inconnues\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eMise en miroir des ports\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePris en charge\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eAgrégation de liens\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePrise en charge de l'agrégation de liens statiques.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eIsolation des ports\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eLes ports d'un groupe d'isolation ne peuvent pas communiquer entre eux.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eQoS\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePlanification WRR et SP et priorité des ports\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eVLAN\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e4094 VLAN\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eSTP\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eSTP et RSTP\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eSNMP\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eSNMPv1 et SNMPv2c pris en charge pour obtenir des informations sur les nœuds du système et des interfaces\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eLLDP\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eLLDP pris en charge pour la configuration des ports, la configuration globale et la découverte des voisins\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eDHCP\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePris en charge\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tech-specs-items-description-wrap\"\u003e\n\u003cul class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eCEM\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eFCC (47 CFR Partie 15, Sous-partie B) ; CE-EMC (EN 55032 : 2015, EN IEC 61000-3-2 : 2019, EN 61000-3-3 : 2013+A1 : 2019, EN 50130-4 : 2011 +A1 : 2014, EN 55035 : 2017) ; IC (ICES-003 : numéro 6) ; MRC (AS\/NZS CISPR 32 : 2015)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eSécurité\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eUL (UL 60950-1) ; CB (IEC 60950-1:2005, AMD1:2009, AMD2:2013, IEC 62368-1 : 2014 (deuxième édition); CE-LVD (EN 60950-1 : 2006 + A11 : 2009 +A1 : 2010+A12 : 2011+A2 : 2013, EN 62368-1 : 2014+A11 : 2017)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eChimie\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eCE-RoHS (2011\/65\/UE) ; DEEE (2012\/19\/UE) ; Reach (Règlement (CE) n°1907\/2006)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"HV-LINE","offers":[{"title":"Default Title","offer_id":43955890192661,"sku":"DS-3E1526P-SI","price":895.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/3208\/5781\/files\/image_temporarily_unavailable.png?v=1784986063","url":"https:\/\/www.hikdistribution.com\/fr-ca\/products\/ds-3e1526p-si-commutateur-poe-intelligent-gigabit-24-ports","provider":"HIKD","version":"1.0","type":"link"}