{"product_id":"24-port-gigabit-full-managed-poe-switch-ds-3e2528p","title":"DS-3E2528P Commutateur POE entièrement géré Gigabit 24 ports","description":"\u003cdiv class=\"product-description-container\" data-product-description-path=\"\/content\/manufacturer\/en\/products\/transmission\/Network-Switches\/Pro-Series\/ds-3e2528p\/jcr:content\/root\/responsivegrid\/product-description\"\u003e\n\u003cdiv class=\"product_description-wrapper eols-wrapper\" data-product-name=\"DS-3E2528P\" data-product-number=\"M000009043\" data-product-page=\"\/content\/manufacturer\/en\/products\/transmission\/Network-Switches\/Pro-Series\/ds-3e2528p\"\u003e\n\u003ch2 class=\"prod_name\"\u003e\u003cspan class=\"prod_name-content\"\u003eSwitch POE entièrement géré Gigabit à 24 ports\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul class=\"product_description_item-list\"\u003e\n\u003cli class=\"product_description_item\"\u003e24 ports électriques Poe Gigabit et 4 ports combo Gigabit.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003ePrend en charge le routage statique, le routage de politique, le rip, OSPF et d'autres protocoles de routage à trois couches.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003eSurveillance IGMP et GRMP pour filtrer le trafic multicast.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003eVLAN basé sur les ports, VLAN IEEE 802.1Q et GVRP pour faciliter la planification du réseau.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003ePrend en charge l'authentification IEEE 802.1x, radius et bdtacacs + authentification.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003ePrend en charge le protocole de protection du réseau en anneau Ethernet EAP et ERP.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003eQoS (IEEE 802.1P\/1Q et TOS\/DiffServ) pour augmenter le déterminisme.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003ePrend en charge le PoE conforme à la norme IEEE 802.3af\/at.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003eChaque port PoE fournit jusqu'à 30 W de puissance de sortie.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003eGestion PoE : détection de périphérique PoE, gestion de l'alimentation PoE.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003eGestion réseau facile par navigateur Web, console, Telnet, SSH.\u003c\/li\u003e\n\u003cli class=\"product_description_item\"\u003eSNMPv1\/v2c\/v3 pour différents niveaux de gestion réseau.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"product_more_out\"\u003e\u003c\/div\u003e\n\u003c!--Parameter--\u003e\n\u003cdiv class=\"firmware-container\"\u003e\n\u003cp\u003eModèles disponibles :\u003c\/p\u003e\n\u003cdiv class=\"ordermodel-list\"\u003e\n\u003cdiv class=\"ordermodel-item\"\u003eDS-3E2528P(B)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDonnées produit\u003c\/h2\u003e\n\u003cdiv class=\"tech-specs-items-description-wrap\"\u003e\n\u003cul class=\"tech-specs-items-description\" data-target=\"Network Parameters\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\u003cspan class=\"tech-specs-items-description__title--heading\"\u003eParamètres réseau\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003ePorts\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePort PoE 24 × 1 Gbit\/s, combo 4 × 1 Gbit\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eTableau des adresses MAC\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e336 Gbit\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eCapacité de commutation\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e56 Gbit\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eTaux de transfert de paquets\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e51 Mpp\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tech-specs-items-description\" data-target=\"PoE Power Supply\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\u003cspan class=\"tech-specs-items-description__title--heading\"\u003eAlimentation PoE\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eNorme PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eIEEE 802.3af, IEEE 802.3at\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eBroche d'alimentation PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e1\/2 (+), 3\/6 (-)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eBudget de puissance PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e370 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tech-specs-items-description\" data-target=\"Software Function\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\u003cspan class=\"tech-specs-items-description__title--heading\"\u003eFonction logicielle\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eVLAN\u003c\/span\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge des identifiants IEEE 802.1Q (VLAN), 4096 VLAN\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du GVRP\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003eSoutenir QinQ\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du VLAN basé sur MAC\/protocole\/sous-réseau IP\/politique\/port\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du VLAN privé\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge des fonctions de mappage VLAN 1:1 et N:1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eQoS\u003c\/span\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la qualité de service Diff-Serv\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du mappage des priorités 802.1p\/DSCP\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la planification des files d'attente, notamment SP, WRR, WFQ, SP+WRR, SP+WFQ\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du marquage et des remarques prioritaires\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la mise en forme du trafic\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrend en charge l'évitement des embouteillages, Tail-Drop et WRED\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du mappage des priorités 802.1p, TOS, DSCP et EXP\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la limitation de débit basée sur le port\/le flux\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eMéthode de gestion\u003c\/span\u003e\n\u003cp class=\"mb-p\"\u003eConsole de support, Telnet, SSH\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge Web, http, https\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge FTP, TFTP, Xmodem, SFTP\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge SNMP V1\/V2c\/V3\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge RMON\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du NTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eMultidiffusion\u003c\/span\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la surveillance IGMP v1\/v2\/v3\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge IGMP V1\/V2\/V3\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la surveillance MLD v1\/v2\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de MLD v1\/v2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eSécurité\u003c\/span\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de l'authentification AAA, TACACS + Radius\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de l'authentification 802.1X, de l'authentification MAC, de l'authentification de contournement MAC\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge pour empêcher DOS, fonction d'attaque ARP, anti-attaque ICMP\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la liaison IP, MAC, port et VLAN\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de l'authentification MAC\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du filtrage d'adresse MAC\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du contrôle des tempêtes de diffusion\/multidiffusion\/inconnu-unicast\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tech-specs-items-description\" data-target=\"General\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\u003cspan class=\"tech-specs-items-description__title--heading\"\u003eGénéral\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003ePoids net\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e3,1 kg (6,83 livres)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eDimensions (L × H × P)\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e440,00 mm × 44,00 mm × 210,00 mm (17,32'' × 1,73'' × 8,27'')\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eTempérature de fonctionnement\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e-10 °C à 50 °C (14 °F à 122 °F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eHumidité de fonctionnement\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e10% à 90% (sans condensation)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eAlimentation\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e100-240 VCA, 50\/60 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eConsommation d'énergie\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e17 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tech-specs-items-description\" data-target=\"Approval\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\u003cspan class=\"tech-specs-items-description__title--heading\"\u003eApprobation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eCEM\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eFCC (ANSI C63.4, 47 CFR PARTIE 15B) ; CE-EMC\/RCM (EN 55032 : 2015+A11:2020, EN IEC 61000-3-2 : 2019, EN 61000-3-3 : 2013+A1:2019, EN 50130-4:2011+A1:2014, EN 55035:2017+A11:2020); IC (ICES-003 : numéro 24)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eSécurité\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eUL (UL 62368-1) ; CB\/RCM (CEI 62368-1:2014) ; CE-LVD (EN 62368-1:2014+A11:2034)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eChimie\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eCE-RoHS (2011\/65\/UE) ; DEEE (2012\/19\/UE) ; Reach (Règlement (CE) n° 1907\/2023)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n,\n\u003cdiv class=\"tech-specs-items-description-wrap\"\u003e\n\u003cul class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003ePorts\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003ePort PoE 24 × 1 Gbit\/s, combo 4 × 1 Gbit\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eTableau des adresses MAC\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e336 Gbit\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eCapacité de commutation\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e56 Gbit\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eTaux de transfert de paquets\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e51 Mpp\/s\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n,\n\u003cdiv class=\"tech-specs-items-description-wrap\"\u003e\n\u003cul class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eNorme PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eIEEE 802.3af, IEEE 802.3at\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eBroche d'alimentation PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e1\/2 (+), 3\/6 (-)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eBudget de puissance PoE\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e370 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n,\n\u003cdiv class=\"tech-specs-items-description-wrap\"\u003e\n\u003cul class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eVLAN\u003c\/span\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge des identifiants IEEE 802.1Q (VLAN), 4096 VLAN\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du GVRP\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003eSoutenir QinQ\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du VLAN basé sur MAC\/protocole\/sous-réseau IP\/politique\/port\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du VLAN privé\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge des fonctions de mappage VLAN 1:1 et N:1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eQoS\u003c\/span\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la qualité de service Diff-Serv\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du mappage des priorités 802.1p\/DSCP\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la planification des files d'attente, notamment SP, WRR, WFQ, SP+WRR, SP+WFQ\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du marquage et des remarques prioritaires\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la mise en forme du trafic\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrend en charge l'évitement des embouteillages, Tail-Drop et WRED\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du mappage des priorités 802.1p, TOS, DSCP et EXP\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la limitation de débit basée sur le port\/le flux\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eMéthode de gestion\u003c\/span\u003e\n\u003cp class=\"mb-p\"\u003eConsole de support, Telnet, SSH\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge Web, http, https\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge FTP, TFTP, Xmodem, SFTP\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge SNMP V1\/V2c\/V3\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge RMON\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du NTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eMultidiffusion\u003c\/span\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la surveillance IGMP v1\/v2\/v3\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge IGMP V1\/V2\/V3\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la surveillance MLD v1\/v2\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de MLD v1\/v2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eSécurité\u003c\/span\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de l'authentification AAA, TACACS + Radius\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de l'authentification 802.1X, de l'authentification MAC, de l'authentification de contournement MAC\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge pour empêcher DOS, fonction d'attaque ARP, anti-attaque ICMP\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de la liaison IP, MAC, port et VLAN\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge de l'authentification MAC\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du filtrage d'adresse MAC\u003c\/p\u003e\n\u003cp class=\"mb-p\"\u003ePrise en charge du contrôle des tempêtes de diffusion\/multidiffusion\/inconnu-unicast\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tech-specs-items-description-wrap\"\u003e\n\u003cul class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003ePoids net\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e3,1 kg (6,83 livres)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eDimensions (L × H × P)\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e440,00 mm × 44,00 mm × 210,00 mm (17,32'' × 1,73'' × 8,27'')\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eTempérature de fonctionnement\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e-10 °C à 50 °C (14 °F à 122 °F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eHumidité de fonctionnement\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e10% à 90% (sans condensation)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eAlimentation\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e100-240 VCA, 50\/60 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eConsommation d'énergie\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003e17 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tech-specs-items-description-wrap\"\u003e\n\u003cul class=\"tech-specs-items-description\"\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eCEM\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eFCC (ANSI C63.4, 47 CFR PARTIE 15B) ; CE-EMC\/RCM (EN 55032 : 2015+A11:2020, EN IEC 61000-3-2 : 2019, EN 61000-3-3 : 2013+A1:2019, EN 50130-4:2011+A1:2014, EN 55035:2017+A11:2020); IC (ICES-003 : numéro 24)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eSécurité\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eUL (UL 62368-1) ; CB\/RCM (CEI 62368-1:2014) ; CE-LVD (EN 62368-1:2014+A11:2034)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"tech-specs-items-description-list\"\u003e\n\u003cspan class=\"tech-specs-items-description__title\"\u003eChimie\u003c\/span\u003e\u003cspan class=\"tech-specs-items-description__title-details\"\u003eCE-RoHS (2011\/65\/UE) ; DEEE (2012\/19\/UE) ; Reach (Règlement (CE) n° 1907\/2023)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"HV-LINE","offers":[{"title":"Default Title","offer_id":43955885441301,"sku":"DS-3E2528P","price":912.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/3208\/5781\/files\/image_temporarily_unavailable.png?v=1784986063","url":"https:\/\/www.hikdistribution.com\/fr-fr\/products\/ds-3e2528p-commutateur-poe-entierement-gere-gigabit-24-ports","provider":"HIKD","version":"1.0","type":"link"}